F244 : Flow Indicator Totaliser
|
Description
Special Features
| Indication through LED | |
| Input selectable as linear / square root. | |
| Normal / Batch mode for operation | |
| Averaging of inputs for turbulent flow. | |
| Programmable low flow cut-off. | |
| Software calibration. |
Applications :
Series F-244 is micro-controller based flow indicator totaliser designed for various industrial applications.These can be used for indication & totalisation of flow. The input can be processed linearly or square rooted.The built-in battery back-up is provided for the memory to avoid loss of data in case of power failure.The micro-controller based design provides full flexibility for flow metering applications.
Additional information
| Operating Modes | : Normal / Batch |
|---|---|
| Input | :Linear / Square Rooted |
| Display | : 4 digit, 0.5” Red LED for Flow Rate & 8 digit, 0.3” Red LED for Totalised Flow |
| Range | : Programmable (0 to 9999) |
| Accuracy | : Better than + 0.25% of F. S. |
| Open Sensor Indication | : Provided |
| Power Supply | : 1) 24 V DC, External |
| Power Consumption | : Less than 10 VA |
| Temperature Drift | : < 0.01% of F. S. per °C change |
| Response Time | : < 100 mSec |
| Isolation | : 1.4 KV between Input, Output & Power Supply |
| Enclosure | : 1) DIN Std |
| Dimensions | : 96 (H) x 96 (W) X 250 (D) in mm approx. for DIN std. enclosure |
| Mounting | ; Flush of the Panel for DIN std. enclosure & wall mount for WP& FLP enclosure |
| Weight | : 2 kg (Approx.) |
| Operating Conditions | : Temperature 0 to 55 0C / Humidity 5 to 95% non condensing |