omicron sensing logo,pressure instrument,temperature instrument
 
Product Range
Pressure Instruments
Temperature Instruments
Level Instruments
Flow Instruments
Humidity Instruments
Cleanroom Instrument
HVAC / BMS Sensors
Air Quality Sensors
Water Quality Sensors
VAV Boxes
BTU Meter
Valves
Indicators & Controllers
- PVI80-4 Digit Universal
  Indicator
- PVI82-4 Digit Controller
  with 2 Relay Outputs
- PVI84-4 Digit Controller
  with 4 Relay Outputs
- EXIC-Process Indicators
  & Controllers
- PVD-Differential
  Pressure Indicator
- PVIH-5 Digit Precision
  Universal Indicator
-FJ-Flow Indicator Totaliser
-T3000-Digital Controller
-DV9800- Universal
Micro Scanner
Datalogger
Portable Instruments
Accessories
 
 Sign Up To Our Newsletter:
PVI82: 4 Digit Controller with 2 Relay Outputs
Model : PVI82
Accuracy : ±0.25%
Retransmission : Optional
Display : 3½ Digits
Relay : 2 SPDT
Inputs : Universal

Features :

Universal input : Accepts Sensor Inputs (Thermocouple or RTD), Current, Voltage, & mV.
High Indication Accuracy: ± 0.25%.
Sensor Error Compensation (of fset) and Break Detection.
2 Alarm outputs.
Status Indicators for outputs.
24 VDC Sensor Supply .
Parameter Security V ia Programmable Lockouts.
85 to 270 VAC/DC supply voltage (also available 24 VDC models - Consult factory).
Compliance: CE, RoHS

Specifications :

Display : 4-digit (7 segment LED) 0.5" high.
Display Messages : “Or” - Appears when measurement exceeds range or open
  sensor is detected.
: “rE” - TC reverse.
Display alternating
between:
: PV & HA-AL No. for high alarm.
  PV & LA-AL No. for low alarm.
LED Status
Annunciators
: Alarm ON ( 2nos) .
Power : 85 to 270 V AC/DC, 50 to 60 Hz, 5 V A max.
Optional : 24 VDC (Consult Factory).
Settings : V ia three keys on front panel.
Memory : Nonvolatile EEPROM retains all programmable parameters   and values.
Main Sensor Input : Universal
Temperature Units : C° / F°.
Resolution : Temperature: 1 / 0.1.
  Signal input: 0.001,
: 0.01, 0.1 & 1 decimal
: Point selectable.
Thermocouple inputs : Alarm ON ( 2nos) .
  J : -200 to 750°C.
  K : -200 to 1350°C.
  T : -200 to 400°C.
  R : 0 to 1750°C.
  S : 0 to 1750°C.
RTD input
( 2 wire or 3 wire)
 
PT100 : -100 to 850°C.
Signal inputs  
Voltage : 0 to 10 VDC.
Current : 0 to 20 mA.
mV(linear) : -5 to 56mV
Indication Accuracy : 0.25% of Span ±1 C (After 20min. W armup)
Control And Alarm Outputs
Relay Output : 5A @ 250V AC or 24VDC.
Optional : 12VDC output to drive SSR.
Output : 2 nos.
Alarm modes : Alarm High, Alarm Low , Band, Fail output & Fault diagnosis.
Hysteresis : Programmable.
Annunciator : Programmable.
Reset Action : Programmable - automatic or latched.
Standby Mode : Programmable - enable or disable. or disable.
Linear Dc Output : Optional
Re-transmission : 0/4 to 20 mA or 0 to 5 V or 0 to 10 V.
  Update rate : 100msec.
Environmental Conditions
Operating Range : 0 to 50°C.
Storage Range : -5 to 50°C.
Humidity : 85% max.
Connection : Wire clamping screw terminals.
Weight : 342 grams
digital temperature controller,digital controller
Download Data Sheet
Request A Quote
Contact Us
 
 